Energy Efficiency and Indoor Climate
Measurement | Air temperature, air velocity, air humidity, globe temperature, global solar radiation, carbon dioxide |
Standard | DIN EN ISO 7730 |
Measurement objects | Offices, conference and living rooms, automotive, aviation, rail-bound vehicles |
Air temperature | -10 up to +60 °C |
Air velocity | 0 to 1 m/s, 0 to 5 m/s |
Air humidity | 5 to 98 % r.h. |
Globe temperature | -10 up to +60 °C |
Global solar radiation | 0 to 1300 W/m² |
Carbon dioxide | 0 to 5000 ppm |
Measurements simultaneously | Temperature measurement radiation shielded. Air temperature and air velocity at three heights, measuring heights between 0.1 and 1.8 m |